EA1791 ETERE REDUNDANCY SWITCH

24 November 2016

A redundancy component to switch the control of devices between main/backup controllers, devices can be connected via GPI or Serial.

The EA1791 is a redundancy switch that enables the switch of multiple main/backup devices, whether controlled via serial (e.g. RS-232 and RS-422) or via GPI.

■The device is based on relay switching so its connections are fully bidirectional
■Etere Redundancy Switch does not make any noise or modify the signal to be switched and the switching is relay controlled
■Lines are independent from one to another, any protocol can be used
■The switching can be manual from the front panel, via a remote controlled GPI or by Etere Automation
■Use of two power supplies for redundancy
■When used with Etere Automation, EA1791 sends SNMP error traps in case one of its power supplies is defective
■One EA1791 is required for each playout channel
■EA1791 is the third version of the former ET0558, now made in Singapore.




Download Pdf Doc.
Download
■ 25 GPI lines on DB25 connection

■ 8 serial lines on RJ45 connector

■ Remote control on RJ45 connector

■ All the pins of the RJ45 are switched via relays
■ Serial connectors 8
■ No. outputs on RJ45 8
■ No. Serial lines switched 8
■ No. GPI lines switched 25
■ GPI connector DB25
■ Switching current 300mA max
■ Switching voltage 50Vcc/Vca max
■ Optical information Output channel
■ Temperature field from + 5 to + 45° C
■ Relative humidity < 90 % non condensing
■ AC supply 220 V 47-63 Hz
■ AC consumption < 90 VA
■ Dimensions Rack standard 19" 1 U (mm.) 45 (H)x 442 (W)x 245 (D)
■ Weight 1,9 kg
ETERE REDUNDANCY SWITCH EA1791
Key Features
■ 25 GPI lines on DB25 connection ■ 8 serial lines on RJ45 connector ■ Remote control on RJ45 connector ■ All the pins of the RJ45 are switched via relays
ETERE REDUNDANCY SWITCH EA1791
Technical Information
■ Serial connectors 8 ■ No. outputs on RJ45 8 ■ No. Serial lines switched 8 ■ No. GPI lines switched 25 ■ GPI connector DB25 ■ Switching current 300mA max ■ Switching voltage 50Vcc/Vca max ■ Optical information Output channel ■ Temperature field from + 5 to + 45° C ■ Relative humidity < 90 % non condensing ■ AC supply 220 V 47-63 Hz ■ AC consumption < 90 VA ■ Dimensions Rack standard 19" 1 U (mm.) 45 (H)x 442 (W)x 245 (D) ■ Weight 1,9 kg